Can I adjust amplitude of Moku:Labs output reference clock ?

Written by Paul Cracknell

Updated at February 4th, 2021

Contact Us

If you still have questions or prefer to get help directly from an agent, please submit a request.
We’ll get back to you as soon as possible.

Please fill out the contact form below and we will reply as soon as possible.

  • Moku:Go
    Moku:Go Arbitrary Waveform Generator Moku:Go Data Logger Moku:Go Frequency Response Analyzer Moku:Go Logic Analyzer & Pattern Generator Moku:Go Oscilloscope & Voltmeter Moku:Go PID Controller Moku:Go Spectrum Analyzer Moku:Go Waveform Generator Moku:Go Power Supplies Moku:Go Digital Filter Box Moku:Go FIR Filter Builder Moku:Go Lock-in Amplifier
  • Moku:Lab
    Windows Moku:Lab general Moku:Lab Instruments iPad app Software integrations
  • Moku:Pro
    Moku:Pro Instruments
+ More

Moku:Labs output reference clock at 10MHz

Moku:Lab provides a reference clock output on the rear panel. This can be used to synchronize to other items of lab test and measurement equipment. 

This clock output is fixed at 10 MHz, -3 dBm (50ohms) or 500 mVpp.

However, many of our instruments (Oscilloscope, Phasemeter, Datalogger, Phasemeter, Spectrum Analyzer) provide an in-built waveform generator. This in-built waveform generator can be used to provide a reference to external equipment; the amplitude and frequency can be adjusted.

Finally, if you are using a Moku:Lab instrument that does NOT integrate a waveform generator; you can use a second Moku:Lab to provide an adjustable amplitude reference output using our Waveform generator instrument. This second Moku:Lab can then be synchornized to the first Moku:Lab via the rear panel reference clocks.

amplitude modulation reference clock sync synchronization synchronize

Was this article helpful?

Yes
No

Related Articles

  • Does Moku:Lab reference to earth ground or it has floating ground?
  • How much current can Moku:Lab source and sink?
  • Can I log to the SD card ?
  • Are the Moku:Labs protected from over voltage ?

Sitemap

  • Moku:Lab
  • Instruments
  • Software
  • Company
  • Support
  • Store
  • Terms & Conditions
  • Privacy Policy

Offices

United States
+1 (619) 332-6230
740 Lomas Santa Fe Dr
Suite 102
Solana Beach, CA 92075

Australia
+61 2 6171 9730
243 Northbourne Avenue
Suite 2
Lyneham, ACT 2602

Follow us

Youtube LinkedIn

官方微信

Contact us
© 2021 Liquid Instruments. All rights reserved.

Definition by Author

0
0
Expand