How to remove drift in Phasemeter measurement

Written by Paul Cracknell

Updated at December 22nd, 2020

Contact Us

If you still have questions or prefer to get help directly from an agent, please submit a request.
We’ll get back to you as soon as possible.

Please fill out the contact form below and we will reply as soon as possible.

  • Moku:Go
    Moku:Go Arbitrary Waveform Generator Moku:Go Data Logger Moku:Go Frequency Response Analyzer Moku:Go Logic Analyzer & Pattern Generator Moku:Go Oscilloscope & Voltmeter Moku:Go PID Controller Moku:Go Spectrum Analyzer Moku:Go Waveform Generator Moku:Go Power Supplies Moku:Go Digital Filter Box Moku:Go FIR Filter Builder Moku:Go Lock-in Amplifier
  • Moku:Lab
    Windows Moku:Lab general Moku:Lab Instruments iPad app Software integrations
  • Moku:Pro
    Moku:Pro Instruments
+ More

Moku:Lab uses a digitally implemented phase-locked loop architecture to measure the phase, frequency, and amplitude of a signal.

If you are seeing an unexpected and constant drift in your phase measurement, it can be due to frequency settings at the output or the input side. You can adjust Moku:Lab's Phasemeter with the following settings to remove drift.

Output frequency setting:

First disengage "Lock" on output frequency then tap "Reacquire" to restart the measurement.

Input frequency setting:

Manually set the frequency at the Input side then tap "Reacquire" to restart the measurement.

phasemeter phase drift phase-locked loop pll moku:lab

Was this article helpful?

Yes
No

Related Articles

  • How does Moku:Lab calculate Allan Deviation?
  • What reference does the Phasemeter measure against?
  • How does Moku:Lab calculate the Power Spectral Density?
  • Phasemeter output waveform resolution

Sitemap

  • Moku:Lab
  • Instruments
  • Software
  • Company
  • Support
  • Store
  • Terms & Conditions
  • Privacy Policy

Offices

United States
+1 (619) 332-6230
740 Lomas Santa Fe Dr
Suite 102
Solana Beach, CA 92075

Australia
+61 2 6171 9730
243 Northbourne Avenue
Suite 2
Lyneham, ACT 2602

Follow us

Youtube LinkedIn

官方微信

Contact us
© 2021 Liquid Instruments. All rights reserved.

Definition by Author

0
0
Expand