Contact Us

If you still have questions or prefer to get help directly from an agent, please submit a request.
We’ll get back to you as soon as possible.

Please fill out the contact form below and we will reply as soon as possible.

  • Knowledge Base Home
  • Contact Us
  • Home
  • Moku:Lab
  • Moku:Lab Instruments
  • Moku:Lab Frequency Response Analyzer

How can I plot the ratio of input 1 and input 2 using the Moku Frequency Response Analyzer?

Written by Paul Cracknell

Updated at May 26th, 2022

Contact Us

If you still have questions or prefer to get help directly from an agent, please submit a request.
We’ll get back to you as soon as possible.

Please fill out the contact form below and we will reply as soon as possible.

  • Moku:Go
    Moku:Go Arbitrary Waveform Generator Moku:Go Data Logger Moku:Go Frequency Response Analyzer Moku:Go Logic Analyzer & Pattern Generator Moku:Go Oscilloscope & Voltmeter Moku:Go PID Controller Moku:Go Spectrum Analyzer Moku:Go Waveform Generator Moku:Go Power Supplies Moku:Go Digital Filter Box Moku:Go FIR Filter Builder Moku:Go Lock-in Amplifier
  • Moku:Lab
    Windows Moku:Lab general Moku:Lab Instruments iPad app Software integrations
  • Moku:Pro
    Moku:Pro Instruments
+ More

By default, each channel shows the ratio of the input to the output, In / Out. This is useful for measuring the transfer function of a device under test. The math channel allows you to plot different combinations of Ch 1 and Ch 2. If the output amplitudes of both channels are set to the same value, then viewing the math channel as Ch 1 / Ch 2 will show the ratio In 1 / In 2, since the outputs are the same.

The In is referencing the input to the Moku, which would be the output of the DUT. The Out is referencing the output of the Moku, which is a swept sine wave and the input to the DUT.

frequency response analyzer fra power ratio in1/in2

Was this article helpful?

Yes
No

Related Articles

  • Frequency Response of EFI / RFI filter
  • Frequency Response Analyzer and harmonics
  • Can Moku:Lab analyze control loops ?
  • Using the Frequency Response analyzer to measure inductance

Sitemap

  • Moku:Lab
  • Instruments
  • Software
  • Company
  • Support
  • Store
  • Terms & Conditions
  • Privacy Policy

Offices

United States
+1 (619) 332-6230
740 Lomas Santa Fe Dr
Suite 102
Solana Beach, CA 92075

Australia
+61 2 6171 9730
243 Northbourne Avenue
Suite 2
Lyneham, ACT 2602

Follow us

Youtube LinkedIn

官方微信

Contact us
© 2021 Liquid Instruments. All rights reserved.

Definition by Author

0
0
Expand