Can I deploy more than one instrument on the same Moku:Lab device?

Written by Paul Cracknell

Updated at December 22nd, 2020

Contact Us

If you still have questions or prefer to get help directly from an agent, please submit a request.
We’ll get back to you as soon as possible.

Please fill out the contact form below and we will reply as soon as possible.

  • Moku:Go
    Moku:Go Arbitrary Waveform Generator Moku:Go Data Logger Moku:Go Frequency Response Analyzer Moku:Go Logic Analyzer & Pattern Generator Moku:Go Oscilloscope & Voltmeter Moku:Go PID Controller Moku:Go Spectrum Analyzer Moku:Go Waveform Generator Moku:Go Power Supplies Moku:Go Digital Filter Box Moku:Go FIR Filter Builder Moku:Go Lock-in Amplifier
  • Moku:Lab
    Windows Moku:Lab general Moku:Lab Instruments iPad app Software integrations
  • Moku:Pro
    Moku:Pro Instruments
+ More

Sequential instrument deployment in MATLAB

You can run multiple instruments with the same Moku:Lab in sequence, but it is not possible to do so at the same time.

To deploy a new instrument, simply connect to the Moku:Lab with a new instrument:

%% Sequential Instrument Deploy Example
% 
% This example demonstrates how you can deploy the Oscilloscope instrument followed
% by the Frequency Response Analyzer instrument
% 
% (c) 2020 Liquid Instruments Pty. Ltd.
%
%% Connect to your Moku
ip = input('Please enter your Moku:Lab IP address: ', 's');

% Connect to your Moku and deploy the Oscilloscope instrument
m1 = MokuOscilloscope(ip);

%% Perform tasks with the Oscilloscope 


% Connect to your Moku and deploy the Frequency Response Analyser instrument
m2 = MokuFrequencyResponseAnalyzer(ip);

%% Perform tasks with the Frequency Response Analyzer

Note: once the Frequency Response Analyzer instrument is deployed, Moku:Lab will not be running the Oscilloscope instrument any more. If you need to access the Oscilloscope again, you will need to deploy the Oscilloscope again.

Was this article helpful?

Yes
No

Related Articles

  • Where can I find the documentation for MATLAB APIs?

Sitemap

  • Moku:Lab
  • Instruments
  • Software
  • Company
  • Support
  • Store
  • Terms & Conditions
  • Privacy Policy

Offices

United States
+1 (619) 332-6230
740 Lomas Santa Fe Dr
Suite 102
Solana Beach, CA 92075

Australia
+61 2 6171 9730
243 Northbourne Avenue
Suite 2
Lyneham, ACT 2602

Follow us

Youtube LinkedIn

官方微信

Contact us
© 2021 Liquid Instruments. All rights reserved.

Definition by Author

0
0
Expand